Series TY-FRB

Horizontal and Vertical Sidewall Sprinklers

Quick Response, Standard Coverage, K-factor=5.6

Features:

  • Light hazard/Ordinary hazard
  • Designed for use in applications where aesthetics must be considered or where building construction makes the installation of standard pendent or upright sprinklers impractical
  • Vertical sidewall sprinkler can be installed in either the pendent or upright position along a wall or the side of a beam and just below a smooth ceiling

Hazard: Light Hazard/Ordinary Hazard

Temperature: 135, 155, 175, 200, 286

Thread: 1/2″

Approval: UL, C-UL, FM, NYC, LPCB

Response: Quick Response

SIN Numbers: TY3431,TY3331

Wrench: W6

Wrench [Recessed]: ,W7

Series TY-FRB

Upright, Pendent, and Recessed Pendent Sprinklers

Quick Response, Standard Coverage, K-factor=5.6

Features:

  • Light hazard/Ordinary hazard light hazard K=5.6
  • Hemispherical water spray pattern in the area beneath the sprinkler
  • Small frame and narrow profile bulb enhance appearance
  • Designed for use in commercial occupancies such as banks, hotels, and shopping malls.

Hazard: Light Hazard/Ordinary Hazard

Temperature: 135, 155, 175, 200, 286

Thread: 1/2″

Approval: UL, C-UL, FM, LPCB, VdS, CE

Response: Quick Response

SIN Numbers: TY313,TY323

Wrench: W6

Wrench [Recessed]: ,W7

Series TY-B

Upright, Pendent, and Recessed Pendent Sprinklers

Standard Response, Standard Coverage, K-factor=5.6

Features:

  • All hazard
  • Discharges a hemispherical water spray pattern in the area beneath the sprinkler
  • Small frame, narrow profile bulb
  • Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.

Hazard: All

Temperature: 135, 155, 175, 200, 286, 360, Open

Thread: 1/2″

Approval: UL, C-UL, FM, LPCB, VdS, CE

Response: Standard Response

SIN Numbers: TY315,TY325

Wrench: W6

Wrench [Recessed]: ,W7

Series TY-B

Horizontal and Vertical Sidewall Sprinklers

Standard Response, Standard Coverage, K-factor=5.6

Features:

  • Light hazard/Ordinary hazard
  • Small frame
  • Unique deflector design of the horizontal sidewall sprinkler results in smaller profile
  • Designed for installation along a wall or the side of a beam just beneath a smooth ceiling
  • Water discharge is directed primarily outward and downward in a quarter spherical pattern
  • Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics
  • Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position

Hazard: Light Hazard/Ordinary Hazard

Temperature: 135, 155, 175, 200, 286, 360, Open

Thread: 1/2″

Approval: UL, C-UL, FM, LPCB, NYC

Response: Standard Response

SIN Numbers: TY3451,TY3351

Wrench: W6

Wrench [Recessed]: ,W7

Series TY-B

  • All hazard
  • Discharges a hemispherical water spray pattern in the area beneath the sprinkler
  • Small frame, narrow profile bulb
  • Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.

Hazard: All

Temperature: 135, 155, 175, 200, 286, 360, Open

Thread: 1/2″,3/4″

Approval: UL, C-UL, FM, LPCB, NYC, VdS

Response: Standard Response

SIN Numbers: TY1151,TY1251,TY4851,TY4951,TY4151,TY4251

Wrench: W6

Wrench [Recessed]: ,W7

Series TY-FRL

Horizontal Sidewall

Quick Response, K-factor=5.6

Features:

  • Light hazard/Ordinary hazard
  • Designed for compact installation along a wall or on the side of a beam just beneath a smooth ceiling
  • Generally used in lieu of pendent or upright sprinklers because of aesthetics, building construction, where piping across the ceiling is not desirable

Hazard: Light Hazard/Ordinary Hazard

Temperature: 165, 212

Thread: 1/2″

Approval: UL, C-UL, FM, NYC

Response: Quick Response

SIN Numbers: TY3321

Wrench: W9

Series TY-FRL

Upright, Pendent, and Recessed Pendent Sprinklers

Quick Response, Standard Coverage, K-factor=2.8, 5.6, & 8.0

Features:

  • Light hazard/Ordinary hazard light hazard K=2.8 (40,3)
  • Typically used in hotels, motels, office buildings and other commercial and industrial applications

Hazard: Light Hazard,Light Hazard/Ordinary Hazard

Temperature: 165, 212

Thread: 1/2″,3/4″

Approval: UL, C-UL, NYC, FM, LPCB

Response: Quick Response

Series TY-L

Upright, Pendent, and Recessed Pendent Sprinklers

Standard Response, Standard Coverage, K-factor=5.6 & 8.0

Features:

  • All hazards
  • Discharges a hemispherical water spray pattern in the area beneath the sprinkler
  • Designed for use in light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc

Series EC-11 and EC-14

Upright and Pendent

Extended Coverage Light and Ordinary Hazard,K-factor=11.2 & 14.0

Features:

  • Light hazard/Ordinary hazard
  • Designed for maximum coverage applications of 400ft2 – 14Ft. x 14Ft. (4,3 m x 4,3 m) up to 20Ft. x 20Ft. (6,1 m x 6,1 m)
  • Low profile decorative glass bulb spray sprinklers

Hazard: Light Hazard/Ordinary Hazard

Temperature: 135, 155, 175, 200,

286, Open

Thread: 3/4″

Approval: UL, C-UL, NYC, FM

Response: QR/SR

SIN Numbers: TY5137,TY5237,TY6137,TY6237

Wrench: W3

Wrench [Recessed]: ,W22